At a glance
Key specifications
Rack format
10" / 1U
Outputs
3 × UK BS 1363
Power input
UK plug + lead
Lead
3m
Switching
Unswitched
Overall size
256 × 45 × 45 mm
Overview
3 UK sockets in a compact 10-inch rack.
Designed for rack-mounted cabinet equipment, this PDU provides a fixed distribution point for 3 UK sockets, with power supplied through a 3m captive UK mains lead.
UK sockets at the rack
Provides 3 UK sockets at the rack, keeping equipment power connections fixed and accessible inside the cabinet.
Compact 10-inch / 1U format
Fits compact 10-inch network cabinets while using a single rack unit.
Surge-protected distribution
Integrated surge protection adds protection for connected rack equipment.
In the box
What’s included
Mounting hardware and accessories supplied with this PDU.
✓
4 × cage nuts
✓
4 × rack screws
✓
4 × washers
Dimensional data
Technical drawing
Dimensional outline generated from the stored product measurements.
Front elevation
Side elevation — switch end
Main body
206 × 45 × 45 mm
Maximum overall dimensions
256 × 45 × 45 mm
Mounting centres
235 mm
Schematic dimensional outline generated from product data. Undimensioned component geometry is illustrative and the drawing is not intended for fabrication.
Technical data
Specifications
Configuration
Rack standard
10"
Rack height
1U
Orientation
Horizontal
Electrical
Nominal voltage
230 V
Frequency
50 Hz
Surge protection
Yes
Mechanical
Body dimensions (W × H × D)
206 × 45 × 45 mm
Overall dimensions (W × H × D)
256 × 45 × 45 mm
Mounting-hole centres
235 mm
Material
Aluminium
Finish
Powder coated
Identification
SKU
PLX-C-MINILINE-UK3H-1UBESPD
EAN
5055606412783
Connections & switching
Output sockets
3 × UK BS 1363
Power input
UK plug + lead
Lead length
3m
Switching
Unswitched
Cable
Conductors
3-core
Conductor size
1.5 mm²
Weight & packaging
Net weight
Approx. 0.68 kg
Packaged weight
0.79 kg
Reviews across this range
Customer reviews
Reviews are shared across closely related product variants, so you can benefit from relevant experience across the range.
How ratings are collected
Some customers leave a star rating without a written review, so the number of ratings may be higher than the number of written reviews. Where available, written reviews display the original review date and the product variant reviewed. For privacy, some earlier reviewer display names have been shortened or replaced.
★★★★☆
4.4
26 ratings
9 written reviews
Showing
of
written reviews
No written reviews for this item
matching reviews
★★★★★
good for a 10" rack
very solidly built, small power strip, not much more to add really, i brought it for a 10" network rack
★★★★☆
Fits GeeekPi T2 rack, mileage may vary with other racks.
Specs are somewhat lacking on the listing (-1 *), so here's more info as someone who bought this specifically to go in a GeeekPi 10" rack.
It fits in a GeeekPi 10" rack well.
Is approx. 213mm from flat-end to flat-end so any rack wider than that should be fine, but you will need to wrangle it in to place as there is an earthing nut next to the cord on one end which prevents it just slotting into place.
Power cord is approx. 2m long.
Includes M6 mounting screws and rack nuts (the 19" standard), which are not compatible with GeeekPi's racks, so you will need to have some 10/32 screws on hand.
The earthing nut on the end does not have much space from the front panel, there is just enough clearance for the GeeekPi's 6mm thick chassis, but worth bearing in mind if using it with other brands.
★★★★★
great pdu
great little unit for a soho cab
★☆☆☆☆
Broken
Broke after a month.
★★★★★
Highly recommend :)
Great for my 10 inch rack mount , fitted perfectly:
★★★★★
works
it works. no problems
★★★★★
Arrived well packaged and on time
Solid product fitted ok into cabinet
★★★★★
Awesome
Awesome product
★★★★★
Five Stars
Good product and works well
No written reviews for this item yet
Be the first to review 10" 1U 3-Way UK Horizontal PDU – Bracket Entry, Surge Protected.
Your review will help other customers considering this exact product.
No matching reviews
Try a different word or phrase.
Range knowledge
Questions & answers
Helpful information gathered across closely related product variants.
What is a rack PDU used for?
General product questions
A rack PDU takes one incoming mains supply and distributes it to several pieces of equipment inside a cabinet or rack.
It keeps the power distribution with the equipment rather than allowing a collection of ordinary extension leads to acquire a life of its own in the bottom of the cabinet.
Are these smart or managed PDUs?
General product questions
No. The current range consists of basic power distribution units.
They do not provide network management, remote monitoring, power metering or remote outlet control.
What is the difference between a horizontal and vertical rack PDU?
General product questions
A horizontal PDU mounts across the rack in the usual way and occupies rack space. A vertical PDU mounts down the side of the cabinet and consumes no front rack units.
Electrically they perform the same basic job; the distinction is mainly where you want the procession of power leads to live.
Does a PDU with more outlets provide more available power?
General product questions
No. More outlets provide more connection points; they do not multiply the capacity of the incoming supply.
The total connected load still has to remain within the limit of the PDU and its input connection.
What is the difference between UK and IEC outlet PDUs?
General product questions
UK versions provide BS 1363 mains sockets for ordinary UK plugs. IEC versions provide C13 outlets for rack-equipment power leads with C14 plugs.
Mixed versions provide both.
The best choice is usually the one that matches the leads already used by the equipment rather than introducing adapters simply for the sake of variety.
Are all of these PDUs surge protected?
General product questions
No. Surge protection is only present on models specifically identified as surge protected.
Do not assume it is included simply because a product is a rack PDU.
Are these PDUs suitable for outdoor use?
General product questions
No. They are intended for indoor use in data cabinets, network racks and similar equipment enclosures.
We do not specify them as weatherproof or for exposed outdoor installation.
Is rack mounting hardware included with the PDU?
General product questions
Yes. The horizontal and vertical PDUs are supplied with four cage nuts, screws and washers for mounting the unit in a compatible rack or cabinet.
Do I need a 10-inch or 19-inch PDU?
Selection
Choose the rack format that matches the cabinet.
The 10-inch horizontal models are intended for 10-inch racks, while the 19-inch range is intended for standard 19-inch cabinets and racks.
How much rack space does a horizontal PDU use?
Mounting
The horizontal models in this range are 1U units.
Allow one rack unit in the appropriate 10-inch or 19-inch mounting plane.
Is the mains lead captive on the BS 1363 plug-input models?
Input Power
Yes. The BS 1363 plug-input models use a captive mains lead rather than a detachable inlet.
Most use a 3m lead, with a longer 5m version where specifically stated.
What does surge protected mean on these PDUs?
Protection
The surge-protected models include an internal surge protection device intended to provide additional protection for connected equipment against transient mains surges.
It is a specific feature of those models, not a characteristic shared by the whole PDU range.
What fuse is fitted in the UK mains plug?
Input Power
The captive BS 1363 supply plug is fitted with a 13A fuse.
Is there an indicator for the surge protection?
Protection
Yes. The surge-protected models have an LED indicator showing the status of the surge protection.
What is the maximum current for each individual PDU outlet?
Load
We do not currently publish a product-specific per-outlet current figure for this PDU range.
Use the verified overall PDU load limit where one is specified and observe the ratings of the connected equipment, connectors and cables.
Are the UK outlets standard BS 1363 sockets?
Outlets
Yes. The UK-output models use standard BS 1363 socket outlets for equipment fitted with ordinary UK mains plugs.
What is the maximum load on the BS 1363 plug-input PDUs?
Input Power
The product label states a maximum total load of 13A for the BS 1363 plug-input models.
That is the total load across the PDU, not 13A for every outlet.
Can I add the theoretical ratings of all the sockets together to work out the PDU capacity?
Load
No. The limiting factor is the complete PDU and its incoming supply, not the arithmetic sum of a row of socket faces.
A bank of outlets is a distribution point, not a small power station.
Use the product-level load limit rather than multiplying one imagined socket rating by the outlet count.
Does a 13A PDU mean I can draw 13A from every socket at the same time?
Input Power
No. The 13A figure is the maximum total load on the BS 1363 input models.
Six sockets do not conjure six independent 13A supplies out of one mains plug.
Add the connected equipment loads together and keep the combined figure within the PDU limit.
What does unswitched mean on a PDU?
Switching
It means there is no master on/off switch on the PDU. The outlets are powered whenever the incoming supply to the PDU is live.
Is a surge-protected PDU the same thing as a UPS?
Protection
No. Surge protection and backup power solve different problems.
The PDU can provide protection against transient surges, but it does not contain a battery and will not keep the equipment running through a power cut.
Expecting it to behave like a UPS would be asking a fairly modest strip of rack-mounted sockets to lead a much more adventurous life than it was designed for.
How do I stay within the 13A maximum load on a UK-plug PDU?
Load
Add the input current of the equipment that will be powered from the PDU and keep the combined load within 13A.
If the equipment load is unclear, check its rating information rather than relying on the number of free sockets as an indication that more load can be added.
What supply voltage and frequency are these PDUs designed for?
Load
The range is specified for a nominal 230V, 50Hz supply.
Can the individual outlets be switched separately?
Outlets
No. The current range does not include individually switched or remotely controlled outlets.
Switched models use one master switch for the complete PDU.
Does each outlet have its own share of the PDU load capacity?
Outlets
No. Think of the outlets as branches from one incoming supply, not as separate little power allocations.
The combined load of everything connected to the PDU is what matters.
How does a 10-inch PDU mount?
Mounting
It mounts horizontally across a compatible 10-inch rack and occupies 1U.
Use the supplied cage nuts, screws and washers at the mounting ears.
Can the surge protection device be replaced?
Protection
No. The surge device is not a user-replaceable component.
If the surge protection is no longer functioning, the PDU should not simply be treated as though replacing an internal cartridge were part of normal maintenance.
Can I use adapters if the PDU has the wrong outlet type for my equipment?
Outlets
A suitable approved adapter may solve a particular connection problem, but choosing the correct PDU or equipment lead is usually cleaner.
Every extra adapter adds another connection, more bulk and another object to accommodate in a cabinet that is rarely short of things already demanding space.
When is a UK-socket PDU the better choice?
Selection
Choose UK outlets when the equipment is already fitted with BS 1363 mains plugs or when you want ordinary UK socket compatibility inside the cabinet.
It is often the straightforward choice for mixed office, telecoms or ancillary equipment that arrives with domestic-style mains leads and would otherwise require a procession of adapters.
What are the PDU bodies made from?
Load
The PDU bodies are aluminium, providing a rigid enclosure suited to rack mounting and other indoor installations.
How many rack fixings are supplied?
Mounting
Four cage nuts, four screws and four washers are supplied with the PDU.
Do any of these PDUs have USB charging ports?
Outlets
No. The current rack PDU range is mains-power only and does not include USB charging ports.