Choose an option to view the corresponding product.
£63.54
ex VAT:
£52.95
ex VAT:
Only 2 available
Limited stock — order now for dispatch next working day.
Price
At a glance
Key specifications
Rack format
19" / 1U
Outputs
16 × IEC C13
Power input
UK plug + lead
Lead
3m
Switching
Unswitched
Overall size
482.6 × 45 × 45 mm
Overview
16 IEC C13 outlets in a single 19-inch rack unit.
Designed for rack-mounted cabinet equipment, this PDU provides a fixed distribution point for 16 IEC C13 outlets, with power supplied through a 3m captive UK mains lead.
IEC C13 distribution at the rack
Provides 16 IEC C13 outlets at the rack for equipment powered by IEC leads, keeping those connections fixed and accessible inside the cabinet.
1U rack mounting
Mounts directly into a standard 19-inch rack and uses a single rack unit.
Unswitched by design
With no integral switch, connected equipment remains powered whenever the PDU supply is live.
In the box
What’s included
Mounting hardware and accessories supplied with this PDU.
✓
4 × cage nuts
✓
4 × rack screws
✓
4 × washers
Dimensional data
Technical drawing
Dimensional outline generated from the stored product measurements.
Front elevation
Side elevation — switch end
Main body
431 × 45 × 45 mm
Maximum overall dimensions
482.6 × 45 × 45 mm
Mounting centres
461.6 mm
Schematic dimensional outline generated from product data. Undimensioned component geometry is illustrative and the drawing is not intended for fabrication.
Technical data
Specifications
Configuration
Rack standard
19"
Rack height
1U
Orientation
Horizontal
Electrical
Nominal voltage
230 V
Frequency
50 Hz
Surge protection
No
Mechanical
Body dimensions (W × H × D)
431 × 45 × 45 mm
Overall dimensions (W × H × D)
482.6 × 45 × 45 mm
Mounting-hole centres
461.6 mm
Material
Aluminium
Finish
Powder coated
Identification
SKU
PLX-C-IEC16H-1U
EAN
5055606412790
Connections & switching
Output sockets
16 × IEC C13
Power input
UK plug + lead
Lead length
3m
Switching
Unswitched
Cable
Conductors
3-core
Conductor size
1.5 mm²
Weight & packaging
Net weight
Approx. 0.9 kg
Packaged weight
1.014 kg
Reviews across this range
Customer reviews
Reviews are shared across closely related product variants, so you can benefit from relevant experience across the range.
How ratings are collected
Some customers leave a star rating without a written review, so the number of ratings may be higher than the number of written reviews. Where available, written reviews display the original review date and the product variant reviewed. For privacy, some earlier reviewer display names have been shortened or replaced.
★★★★★
5.0
3 ratings
2 written reviews
Showing
of
written reviews
No written reviews for this item
matching reviews
★★★★★
Well made at a good price
Well engineered and well made. Does the job perfectly. Good price and quick delivery
★★★★★
10/10
Life saver. Use it for my lighting setup when out DJ'ing.
No written reviews for this item yet
Be the first to review 19" 1U 16-Way IEC C13 Horizontal PDU – Unswitched.
Your review will help other customers considering this exact product.
No matching reviews
Try a different word or phrase.
Range knowledge
Questions & answers
Helpful information gathered across closely related product variants.
What is a rack PDU used for?
General product questions
A rack PDU takes one incoming mains supply and distributes it to several pieces of equipment inside a cabinet or rack.
It keeps the power distribution with the equipment rather than allowing a collection of ordinary extension leads to acquire a life of its own in the bottom of the cabinet.
Are these smart or managed PDUs?
General product questions
No. The current range consists of basic power distribution units.
They do not provide network management, remote monitoring, power metering or remote outlet control.
What is the difference between a horizontal and vertical rack PDU?
General product questions
A horizontal PDU mounts across the rack in the usual way and occupies rack space. A vertical PDU mounts down the side of the cabinet and consumes no front rack units.
Electrically they perform the same basic job; the distinction is mainly where you want the procession of power leads to live.
Does a PDU with more outlets provide more available power?
General product questions
No. More outlets provide more connection points; they do not multiply the capacity of the incoming supply.
The total connected load still has to remain within the limit of the PDU and its input connection.
What is the difference between UK and IEC outlet PDUs?
General product questions
UK versions provide BS 1363 mains sockets for ordinary UK plugs. IEC versions provide C13 outlets for rack-equipment power leads with C14 plugs.
Mixed versions provide both.
The best choice is usually the one that matches the leads already used by the equipment rather than introducing adapters simply for the sake of variety.
Are all of these PDUs surge protected?
General product questions
No. Surge protection is only present on models specifically identified as surge protected.
Do not assume it is included simply because a product is a rack PDU.
Are these PDUs suitable for outdoor use?
General product questions
No. They are intended for indoor use in data cabinets, network racks and similar equipment enclosures.
We do not specify them as weatherproof or for exposed outdoor installation.
Is rack mounting hardware included with the PDU?
General product questions
Yes. The horizontal and vertical PDUs are supplied with four cage nuts, screws and washers for mounting the unit in a compatible rack or cabinet.
Do I need a 10-inch or 19-inch PDU?
Selection
Choose the rack format that matches the cabinet.
The 10-inch horizontal models are intended for 10-inch racks, while the 19-inch range is intended for standard 19-inch cabinets and racks.
How much rack space does a horizontal PDU use?
Mounting
The horizontal models in this range are 1U units.
Allow one rack unit in the appropriate 10-inch or 19-inch mounting plane.
Is the mains lead captive on the BS 1363 plug-input models?
Input Power
Yes. The BS 1363 plug-input models use a captive mains lead rather than a detachable inlet.
Most use a 3m lead, with a longer 5m version where specifically stated.
What type of plug connects to an IEC C13 PDU outlet?
Outlets
The PDU outlet is IEC C13, so the plug inserted into it is an IEC C14 male connector.
A common rack jumper lead therefore has a C14 plug at the PDU end and a C13 connector at the equipment end.
What fuse is fitted in the UK mains plug?
Input Power
The captive BS 1363 supply plug is fitted with a 13A fuse.
What is the maximum current for each individual PDU outlet?
Load
We do not currently publish a product-specific per-outlet current figure for this PDU range.
Use the verified overall PDU load limit where one is specified and observe the ratings of the connected equipment, connectors and cables.
How does a 19-inch horizontal PDU mount?
Mounting
It mounts across the standard 19-inch rack rails in 1U.
Four cage nuts, screws and washers are supplied, so fit the cage nuts at the required U position and secure the PDU through its mounting ears.
What is the maximum load on the BS 1363 plug-input PDUs?
Input Power
The product label states a maximum total load of 13A for the BS 1363 plug-input models.
That is the total load across the PDU, not 13A for every outlet.
Can I add the theoretical ratings of all the sockets together to work out the PDU capacity?
Load
No. The limiting factor is the complete PDU and its incoming supply, not the arithmetic sum of a row of socket faces.
A bank of outlets is a distribution point, not a small power station.
Use the product-level load limit rather than multiplying one imagined socket rating by the outlet count.
Does a 13A PDU mean I can draw 13A from every socket at the same time?
Input Power
No. The 13A figure is the maximum total load on the BS 1363 input models.
Six sockets do not conjure six independent 13A supplies out of one mains plug.
Add the connected equipment loads together and keep the combined figure within the PDU limit.
What does unswitched mean on a PDU?
Switching
It means there is no master on/off switch on the PDU. The outlets are powered whenever the incoming supply to the PDU is live.
How do I stay within the 13A maximum load on a UK-plug PDU?
Load
Add the input current of the equipment that will be powered from the PDU and keep the combined load within 13A.
If the equipment load is unclear, check its rating information rather than relying on the number of free sockets as an indication that more load can be added.
What supply voltage and frequency are these PDUs designed for?
Load
The range is specified for a nominal 230V, 50Hz supply.
Can the individual outlets be switched separately?
Outlets
No. The current range does not include individually switched or remotely controlled outlets.
Switched models use one master switch for the complete PDU.
Does each outlet have its own share of the PDU load capacity?
Outlets
No. Think of the outlets as branches from one incoming supply, not as separate little power allocations.
The combined load of everything connected to the PDU is what matters.
Are the IEC C13 outlets locking?
Outlets
No. They are ordinary IEC C13 outlets and do not have an additional locking or retention mechanism beyond the normal fit of the IEC connector.
Can I use adapters if the PDU has the wrong outlet type for my equipment?
Outlets
A suitable approved adapter may solve a particular connection problem, but choosing the correct PDU or equipment lead is usually cleaner.
Every extra adapter adds another connection, more bulk and another object to accommodate in a cabinet that is rarely short of things already demanding space.
What are the PDU bodies made from?
Load
The PDU bodies are aluminium, providing a rigid enclosure suited to rack mounting and other indoor installations.
When is an IEC C13 PDU the better choice?
Selection
IEC C13 outlets are particularly convenient for rack equipment designed around IEC power connections.
They keep the power arrangement compact and let you use suitably rated IEC jumper leads rather than carrying UK plugs and socket bodies throughout the cabinet.
How many rack fixings are supplied?
Mounting
Four cage nuts, four screws and four washers are supplied with the PDU.
Do any of these PDUs have USB charging ports?
Outlets
No. The current rack PDU range is mains-power only and does not include USB charging ports.
No matching questions