12U 19-inch wall-mounted data cabinets
12U 19-inch Data Cabinets
Shop 12U 19-inch data cabinets and enclosed wall-mounted network racks when your installation needs additional vertical rack space. Compare available depths and assembly options, check your equipment’s mounting requirements and plan the complete loaded weight before installation.
Refine products Optional filters — cabinet size, depth and price
Filters
Compare 12U data cabinets
Compare depths and assembly choices for 12U 19-inch cabinets, using current catalogue prices and availability.
-
12U 600mm Deep 19"
-
12U 450mm Deep 19"
-
12U 300mm Deep 19"
Planning a 12U network cabinet
A 12U cabinet gives you room for a larger network installation, but it is worth planning the layout and wall mounting carefully. Check the equipment depth, total loaded weight and access before choosing a model.
Plan the full installation
Plan where the patch panels, switches, PDUs and shelves will sit, allowing space for cables and access. Put particularly heavy items low down where practical and use any rear support required by the equipment manufacturer. There is no need to fill every U immediately.
Pick the depth for your equipment
Our 12U cabinets are available in different depths. Check the recommended equipment depth rather than relying on the outside cabinet measurement. Rear power plugs, connectors and cable bends can use a surprising amount of room.
Make sure the wall can support it
A loaded 12U cabinet can be substantial. Add the cabinet’s weight to the weight of everything you plan to install, then choose wall fixings and a mounting position suitable for the structure. The cabinet’s payload rating is not a rating for your wall or fixings.
Need help planning your installation? Try the Cabinet Finder or use the Cabinet Builder to select compatible accessories.
12U Data Cabinets: Your Questions Answered
Guidance on larger rack layouts, supporting heavier equipment, choosing cabinet depth and assessing the complete wall-mounted load.
How do I work out how many U of cabinet space I need?
Add together the rack space required by everything you intend to mount: patch panels, switches, shelves, horizontal PDUs, cable managers and any other rack-mounted equipment.
Then consider equipment sitting on shelves. The shelf may occupy 1U at its mounting position, but the equipment resting on its platform may extend through that U and require additional clear space above it.
Finally, leave some room for growth if possible. A cabinet calculation that arrives at exactly 12U for a 12U cabinet is mathematically impeccable and operationally rather optimistic.
Where should particularly heavy equipment such as a UPS be positioned?
Low down where practical.
That isn’t because the bottom of the cabinet possesses some special cooling property. It’s primarily mechanical: keeping heavy equipment lower reduces the height of the combined centre of mass and generally improves stability.
Take the same heavy UPS and move it from the bottom of a freestanding cabinet to the highest available U. The UPS hasn’t changed at all, but you’ve deliberately moved a substantial mass further from the supporting surface and made the whole arrangement less forgiving if it’s disturbed.
The UPS still needs whatever mounting rails or rear support its manufacturer specifies.
Does every rack-mounted device need rear support as well as front mounting ears?
No. Plenty of lightweight, shallow rack equipment is designed to hang perfectly happily from its front mounting ears.
Heavier or deeper equipment is a different matter. Some devices require rear support brackets, fixed rails or sliding rails, and the manufacturer's mounting instructions should take precedence.
A shallow patch panel and a deep UPS may both be described as “rack mounted”, but mechanically they’re asking rather different things of the cabinet. Don’t assume the front ears are sufficient simply because the device can initially be persuaded to hang from them.
Where additional support is specified, use it.
How much weight must the wall and its fixings actually support?
The whole lot.
If the cabinet weighs 20kg and you put 50kg of equipment inside it, the wall is supporting approximately 70kg. Describing the equipment as being within a 60kg cabinet rating doesn’t make the cabinet's own 20kg disappear.
And the cabinet rating tells you what the cabinet can carry. It doesn’t certify the brick, block, timber, plasterboard or whatever fixing system sits between the cabinet and the building.
Wall capacity and cabinet capacity are separate questions. Both need satisfactory answers.
What is the difference between a ready-assembled and flat-packed 19-inch cabinet?
Functionally, very little once both are assembled correctly.
The ready-assembled cabinet arrives built, with the door, side panels, mounting profiles, cable-entry covers, locks and bonding components already fitted. The flat-packed version arrives as the same basic cabinet construction in pieces and needs assembling before use.
One practical advantage of the flat-packed version is access. In pieces, it can pass through openings that a fully assembled cabinet may not. A loft hatch is a good example: the finished cabinet might have no realistic chance of getting through it, while the individual panels can be carried up and the cabinet assembled in position.
You’re choosing between factory assembly and doing the assembly yourself, not between two different grades of cabinet.
The flat-pack version hasn’t sacrificed structural integrity for the privilege of fitting into a flatter cardboard box. Once assembled correctly, it’s intended to perform the same job as the ready-assembled version.
What is the difference between nominal cabinet depth and usable internal depth?
The nominal cabinet depth describes the overall depth class of the enclosure — for example 300mm, 450mm, 550mm or 600mm.
The usable internal depth is the space available inside the cabinet after allowing for the front door, rear structure and other parts of the enclosure. It is therefore smaller than the nominal depth.
Approximate usable internal depths are 250mm for a 300mm cabinet, 400mm for a 450mm cabinet, 500mm for a 550mm cabinet and 550mm for a 600mm cabinet.
Usable internal depth should not automatically be treated as suitable equipment depth because connectors, cable bends, rail position and front-door clearance also require space.