19" 1U 16 Port Cat6 Patch Panel

19" 1U 16 Ports Cat6 Unshielded
SKU: DLX-C-PP-16E-C6-C2G
EAN: 5055606401084
A rack-mounted termination point for permanent Cat6 cabling, bringing 16 cable runs from rear IDC terminations to front-facing RJ45 ports for orderly patching to network equipment.

Available options

Choose Patch Panel

Ports
16 24 48
Category
Cat5e Cat6

Choose an option to view the corresponding patch panel.

£31.96
ex VAT: £26.63
In stock — 98 available Order now for dispatch next working day.

At a glance

Key features

19" / 1U

Rack format

Fits standard network racks and cabinets.

16 ports

Ports

2 banks × 8

Cat6

Performance

Up to 250 MHz

Krone-type IDC

Termination

22–24 AWG

Fixings supplied

Included

4 cage nuts, screws & washers + 4 cable ties

Overview

Bring 16 permanent network runs neatly onto the front of the rack.

Use this panel as the fixed hand-off point between permanent Cat6 installation cabling and patch leads in the rack, keeping fixed cable runs undisturbed while connections to network equipment are managed from the front.

Permanent cabling, accessible patching

Rear Krone-type IDC termination brings each fixed cable run to a front-facing RJ45 port, keeping permanent cabling separate from day-to-day patching.

16 ports in 1U

Brings 16 front-facing patching points into a single rack unit in a standard 19" cabinet.

Two banks of eight

Groups the 16 RJ45 ports into two clear banks of eight across the front of the panel.

In the box

What’s included

Rack-mounting hardware and installation accessories supplied with this panel.

4 × Cage nuts
4 × Rack screws
4 × Washers
4 × Cable ties

Dimensional data

Patch panel technical drawing

Proportional front-port layout generated from measured panel geometry.

Front elevation
Overall width 483 mm 44 mm Mounting centres 465 mm RJ45 positions use measured within-bank and inter-bank centre geometry.
Side elevation
IDC assembly Overall depth 28 mm Metal return 15 mm FRONT REAR
Overall 483 × 44 × 28 mm Body width 442 mm Mounting centres 465 mm Mounting slots 12 × 7 mm Port layout 1 × 16 RJ45 aperture 15 × 16 mm Port array span 315 mm Individual label 14 × 6 mm IDC bank 145 × 14.5 mm Metal return 15 mm

Schematic dimensional outline generated from measured product data. Undimensioned component geometry is illustrative and the drawing is not intended for fabrication.

Technical data

Specifications

Configuration
Product type
Populated patch panel
Rack standard
19"
Rack height
1U
Network category
Cat6
Port count
16 ports
Port arrangement
1 row × 16 ports
Port grouping
2 banks × 8 ports
Shielding
Unshielded
Connections & termination
Front connection
RJ45
Rear termination
IDC
Conductor gauge
22–24 AWG
IDC retermination life
≥20 cycles
Recommended tool
Krone Type Impact Tool
Front layout & labelling
Port banks
2 × 8-port banks
Port carrier size
125 × 16 mm
Individual label size
14 × 6 mm
Label type
Fixed individual labels above each RJ45 port
Mechanical
Overall dimensions
483 × 44 × 28 mm
Main body width
442 mm
Mounting centres
465 mm
Mounting slots
12 × 7 mm
Weight & packaging
Net product weight
458 g
Packaged weight
601 g
Carton dimensions
515 × 60 × 93 mm
Supplied items
Cage nuts
4
Rack screws
4
Washers
4
Cable ties
4
Performance
Rated frequency
Up to 250 MHz
Performance verification
Fluke DSX-8000 tested — Pass
Test platform
Fluke Networks Versiv / DSX-8000
Test configurations
TIA Channel / Permanent Link; ISO/IEC 11801 Permanent Link
Channel compliance
Cat6 channel compliant
Tested to
ANSI/TIA-568 and ISO/IEC 11801
Standards & compliance
ISO/IEC 11801
Compliant
EN 50173
Compliant
ANSI/TIA-568
Compliant
IEC 60603-7 series
Compliant
RoHS
Supplier listed
REACH
Supplier listed
Construction & contacts
Metal material
SPCC steel
Plastic material
ABS
Metal thickness
1.5 mm
Finish
Powder coated
Colour
Black
RJ45 / IDC housing
PBT
Flammability rating
94-V1
RJ45 contact material
Phosphor bronze
RJ45 contact plating
Nickel
Gold plating thickness
3 μin
Rear IDC & cable management
Rear IDC banks
2 × 8-port banks
IDC bank size
145 × 14.5 mm
IDC strip length
30 mm
Clear gap between IDC strips
3 mm
Wiring-code label area
130 × 22 mm
Integrated cable-tie hooks
0 hooks at 0 positions
Electrical & durability
Contact resistance
≤ 20 mΩ
Insulation resistance
≥100 MΩ
Dielectric withstand
1000 VDC contact-to-contact for 60 s
Current rating
1.5 A
Plug retention force
50 N
Plug mating life
750 cycles
Environmental
Operating temperature
-10°C to +60°C
Storage temperature
-20°C to +70°C

Complete the installation

Works with this product

Useful products and installation guidance for this patch panel.

Reviews across this range

Customer reviews

Reviews are shared across closely related product variants, so you can benefit from relevant experience across the range.

How ratings are collected

Some customers leave a star rating without a written review, so the number of ratings may be higher than the number of written reviews. Where available, written reviews display the original review date and the product variant reviewed. For privacy, some earlier reviewer display names have been shortened or replaced.

★★★★★
5.0 3 ratings 1 written review
Showing of written reviews
No written reviews for this item
matching reviews
★★★★★

Five Stars

Excellent price. Unusual to find a 16 port panel - exactly what I needed!

Pamela S. 14 August 2015 Reviewed: 1U 16 Port Cat5e

No written reviews for this item yet

Be the first to review 19" 1U 16 Port Cat6 Patch Panel.

Your review will help other customers considering this exact product.

No matching reviews Try a different word or phrase.
Range knowledge

Questions & answers

Helpful information gathered across closely related product variants.

Browse IDC Patch Panels help
50 questions
Quick answers

Featured questions

Topic

All questions

50 questions
Topic

Installation & termination

14 questions
Topic

Cabling & connections

9 questions
Topic

Speed & compatibility

13 questions
Topic

Ports & panel layout

5 questions
Topic

Rack mounting & cable management

9 questions
Search

Matching questions

Searching questions, answers and topics
Do I need a punchdown tool to wire this patch panel? Installation & termination

Yes. Use a proper punchdown tool.

The rear of the panel is IDC, and trying to seat all those conductors with whatever happens to be in the toolbox is asking for a bad termination.

Why use a patch panel instead of putting plugs straight onto the permanent cables and connecting them to a switch? Cabling & connections

You can put plugs on permanent cables and take them straight into a switch, particularly in a very small installation.

A patch panel starts earning its place as the network grows: the building cables stay fixed and all the inevitable moving, changing and repatching happens with short leads at the front.

Without that separation, it is surprisingly easy to end up wrestling a thicket of permanent cables whenever equipment changes.

Does every wall outlet I want to use need a patch lead from the panel to a switch or router? Cabling & connections

Yes. If you want a wall outlet active, patch its panel port into a suitable switch or router LAN port. A terminated port that is not patched goes nowhere.

Does adding a patch panel to the cable run reduce the network speed? Speed & compatibility

Not when the panel is the correct category and properly terminated. A patch panel is a normal part of a structured-cabling channel; it is not a deliberate speed restriction.

If performance drops after adding one, look for a poor termination, damaged cable or a lower-category component rather than blaming the existence of the panel itself.

Is Gigabit Ethernet fine through the Cat6 version? Speed & compatibility

Yes. Gigabit Ethernet is well within the intended capability of a properly installed Cat6 channel.

If you are only seeing 100Mbps, there is almost certainly a more interesting culprit somewhere in the cable, terminations or connected equipment.

Will the 19-inch versions fit a normal 19-inch network rack or cabinet? Rack mounting & cable management

Yes. The 19-inch populated IDC panels use the standard 19-inch rack format, so they are intended for normal 19-inch network racks and cabinets.

The remaining fit questions are the ordinary ones — available rack units, depth and neighbouring equipment — rather than some peculiar proprietary mounting system.

No matching questions Try a different word or phrase.
Explore

Browse by topic

Write Your Own Review
You're reviewing: 19" 1U 16 Port Cat6 Patch Panel
Your Rating:
loader
Loading...

You submitted your review for moderation.